There are numerous connection possibilities for the perfect connection: As needed, we deliver your thermocouple with a suitable feed through or plug socket – for use in temperatures up to 200°C, up to 650°C or also high temperatures up to 2,200°C.
Can also be delivered with PTFE clamping ring on request.
Note: The permissible operating pressure changes with increasing temperature. Depending on the material and the design of the structure on the customer’s side, the permissible operating pressure can touch 200°C.
For metal cutting rings:
Maximum permissible operating temperature = 650°C
Maximum permissible operating pressure at 20°C = 500 bar
For PTFE clamping rings:
Maximum permissible operating temperature = 200°C
Maximum permissible operating pressure at 20°C = 200 bar