MINERAL INSULATED MANTLE HEAT CONDUCTOR WITH SEAMLESS COLD ENDS – CUSTOMER-SPECIFIC

 

Mineral insulated heat conductors, made up of a live inner wire (filament) which is insulated against the metal sheath with magnesium oxide in the hot part and in the cold part. In particular, the diameter and the composition of the inner wires influence the resistance of the cabling and therefore the heating power of the heat conductor. A high quality sheath material decides the maximum usage temperature and resistance under particular surrounding conditions.

 

What is special about our customer-specific solution is that the lengths of the hot part and the cool part can be defined with the help of the table below according to your wishes. Moreover, we offer you a large selection of individual solutions.

 

We will be happy to make your sheath heat conductor with seamless cold ends ready-made with ceramic power connectors or extension cables.

 

We will of course be happy to support you in calculating the heat conductor and to answer questions you have in connection with your heating application.

We are looking forward to your inquiry.

Mineral insulated mantle heat conductor MKV/MKI – customer specific

 

Wire resistanceOhms/m at 20°C:
Design in mantle materialDiameter heating element in mmMinimum length Heating element in mmHeating elementCold end
Stainless steel 1.4541 (MKV), Inconel 600 (MKI)1,025012,5< 1,3
Stainless steel 1.4541 (MKV), Inconel 600 (MKI)1,52505,5< 0,6
Stainless steel 1.4541 (MKV), Inconel 600 (MKI)2,02503,1< 0,3
Stainless steel 1.4541 (MKV), Inconel 600 (MKI)3,02501,4< 0,2
Stainless steel 1.4541 (MKV), Inconel 600 (MKI)> 3,0250

 

Tolerances:

Outer diameter +/- 0,05mm
Bending radius: 2-3x outer diameter
Length tolerance heating section: +/- 10%
Resistance: +/- 10%